200G/H touch screen intelligent ozone machine

200G/H touch screen intelligent ozone machine
  • 产品介绍

technical parameter

-----------------------------------------------------------------------------

Name: TS-200G/H intelligent ozone machine

Working voltage: AC220V/50HZ, AC220V/60HZ, AC110V/60HZ. Choose one of them.

Power consumption: less than 2.2KW

Air supply: dry clean oxygen or air.

Ozone output: 92% when oxygen flow rate is 60L/min, ozone output is more than 200G/H

When the air flow rate is 120L/MIN, the ozone output is more than 60G/H

Working environment temperature: -10 ~ 40 C

Working environment humidity: less than 85%

Outline size: 750*550*1360mm

The cooling water flow rate is greater than or equal to 15L/min, and the water temperature is not higher than the ambient temperature.

Gross weight / net weight: 100KG/92KG


product mix

-----------------------------------------------------------------------------

1, the product shell is made of 304 stainless steel, with beautiful appearance, durable and humanized design.

2, large 7 inch human-machine interface touch-screen, intelligent numerical control, manual / automatic omnidirectional monitoring.

3, with internal pressure sensor, pressure sensor, temperature sensor, humidity sensor (ozone concentration sensor), all values (including voltage, current, voltage, discharge live room live, air pressure, cooling water is opened, the ambient temperature, the use of environmental humidity, ozone tube temperature rise Etc.) will be real-time feedback to the touch screen, touch screen control system for data analysis in accordance with the factory settings by automatic adjustment, intelligent integration.

4, the internal ozone generator with high frequency and high voltage narrow gap discharge, high efficiency and high yield and high concentration, high voltage power supply yield ratio can be up to 7 ~ 8KW.h/kgO3.

5, the dielectric material by dehydroxy silica quartz material made of high temperature, high precision, uniform discharge, 316L stainless steel electrode and tight firmware, PTFE firmware, 316/304 stainless steel joint, corrosion resistant high pure fluorine rubber ring seal, external cooling using our patented sunflower Aluminum Alloy cooling technology (Patent No. 201030271620.1), effective heat dissipation, long time ozone ultra low attenuation is less than 5/100, the service life is long, up to 32000 hours.

6, high voltage power supply features: IGBT drive, automatic / manual boot, bandwidth slow start, (limiting surge current), power supply overvoltage protection device. Overheat protection, power converter output short circuit protection. Circuit anti-interference, moisture-proof, anti-corrosion design.

7, the high voltage package features: the use of amorphous materials, low temperature, small volume, high radiation disturbance, high packet performance than the traditional black core winding stability, long service life.

8, using 10MM epoxy glass filler plate as insulation fixing plate, high structural strength, long service life, ozone discharge tube installation base adopts high voltage insulation pad, pressure 20KV, high pressure is far greater than the maximum ozone power supply, the maximum extent to ensure the safety performance of the equipment.

9. Use four sets of 60G/H ozone suite to install. The highest yield can reach 240G/H, ensuring enough output.

10, the internal ozone connection pipe is stainless steel or tetrafluoroethylene material. Corrosion resistance and long service life


 

臭氧机内部安装图

1542440045012097969.png

1542440053524071081.png

1542440063162026615.png

1542440070804037294.png

1542440081329071289.png

1542440088674089757.png

1542440096082074645.png

1542440103224016698.png

1542440110062015585.png

Operation instructions of touch screen control center


1, the boot screen is as follows: (background LOGO can be set according to customer requirements)


1542439275221071504.jpg


Select the corresponding menu button to enter the corresponding language interface. This note takes Chinese as an example.


2. After selecting the "enter" or "Enter" interface, the picture is as follows:


 

1542439339216024542.jpg

 

Touch to select the interface that needs to be entered:

System parameter setting

Alarm parameter setting

Working interface

Alarm browsing

Buzzer on / off

Return


3, system parameter setting (after entering the interface can set the system time, backlight duration)


1542439373929064385.jpg


4, set the alarm parameters (here set the alarm parameters, the factory has the equipment, no abnormal goods do not debug reference data for debugging)


1542439393164090974.jpg


reference value:


最大工作电压

230V

最大气源湿度

85%RH

最大工作电流

12000mA

最大臭氧浓度

300mg/L

最高发生器温度

60℃

臭氧浓度显示比例

100mg/L


5, work interface:


1542439531178050978.jpg


 

This interface for working interface, the corresponding key functions are as follows: (before make sure if there is no alarm, alarm, according to the ScreenTip check, start, please ensure that the cooling water flow, air flow meter open, open)

Start button: under manual mode, press this button to start the ozone generator.

Stop button: press this button to stop the ozone generator.

Manual and automatic buttons: press this button to switch between manual and automatic functions.

The default A, a system for automatic operation, in the following way can exit this key, mode conversion

B, working time settings can be clicked in the corresponding digital position, and the corresponding data is adjusted.

C, in any way, the power adjustment is manual.

Output + button: press this button, the production progress bar will add 1 until 10.

Output button: press this button, the production progress bar will be reduced by 1 until 0.

Return key: the system will switch to the previous interface.

Work mode key: press this button to enter work mode:


 

1542439563519082510.jpg

The working time is set in sequence. The upper and lower limits of ozone concentration regulation are set. The upper limit must be higher than the lower limit. Otherwise, it will not work (reference data: the upper limit is 300 mg/L, the lower limit is 0 mg/l).


6, alarm browsing (record every ozone generator failure time and fault location).

1542439602499084696.jpg

7. Buzzer on / off.

Press this button to turn on or turn off the buzzer that has failed to alarm.


8. Return

Pressing this key will return to the previous working interface.


Instructions for equipment use

-----------------------------------------------------------------------------

TS-100G/H is a humanized intelligent ozone machine, ideal equipment for water treatment and air purification and sterilization processing, widely used in water treatment, sewage treatment, pharmaceutical industry operating room, sterile workshop, food processing industry, storage room, training room, mushroom farms, large laundry room, large hotels, central air-conditioning etc..


Equipment installation instructions

-----------------------------------------------------------------------------

1, the equipment should be placed in a dry, clean, well ventilated environment where the temperature is not greater than 45 degrees.

2, through the cooling water inlet and outlet pipe, connected to gas source (oxygen or air) pipeline, switch on the power line, to ensure that water, gas pipeline leak, open the machine protection switch, the touch screen control center to display user interface.

3, manual on the touch screen to enter the system, work settings, set the working time cycle, ozone, ozone output value, output value, etc.. After the set, we can choose to start work, the machine will automatically work in accordance with the values you set, and in accordance with the factory set to protect the data monitoring, once the failure of a link, the machine will alarm and display is the site of failure, and stop working to ensure a high voltage discharge. Prepare for normal and stable use, omnibearing intelligent monitoring and control.


Points for attention

1. After sealing, check whether the random accessories are complete and the equipment is in good condition according to the packing list.

2, do not collision during moving, so as not to damage.

3, if do not need to install the equipment, please do not open the plastic film sealing machine, stored in a dry and ventilated place.

4, equipment installed in a well ventilated clean environment, can not be inverted or flat. Installation location can not be poured by rainwater and environment humidity is greater than 90%.

5, prohibit the use in inflammable and explosive places.

6, do not plug the machine vents, otherwise it will affect the temperature inside the machine will lead to the ozone generator ozone concentration decreased, reduced service life.

7, ozone as a strong oxidant, high ozone concentration of ozone exit out of the body, not a long time contact with ozone, ozone can be put into the confined space in the machine to stop working after 60 minutes of natural decomposition, we can enter.

8, non professionals, do not open the case, the general electrician personnel need to professional maintenance personnel in the ozone machine after consultation can open the case.


Daily maintenance of equipment

-----------------------------------------------------------------------------

1, the use of equipment should be placed in dry ventilated and clean environment, the ambient temperature between -10 to 40 DEG C, relative humidity is less than 85%.

2, the maintenance of equipment, the need to cut off the power supply, cooling water, oxygen bottle or air compressor case through the line.

3, regular inspection ventilation equipment on the line, to remove the clean and put back in situ as more dust.

4, the equipment can be a long time to 24 hours of continuous work, but please make sure that the flow of cooling water in normal temperature, normal (not higher than the ambient temperature, good ventilation cooling equipment).

5, the wet towel used for cleaning the chassis must be twisted dry and used. Do not splash the water into the machine.

  报错


上一页
下一页