电商详情
当前位置: 首页> 电商详情

产品详情

100G/H touch screen ozone machine

100G/H touch screen ozone machine
  • 产品介绍

Control panel diagram

1542439160013055555.jpg

 

Leave-off switch: It can be used to control other equipment, such as air source equipment and cooling water equipment switch (not used).

Gas flow regulation: control the volume of gas flow, increase clockwise and counter clockwise.

Power indicator: when the power is turned on, the lamp will always shine.

Operation indicator: after the touch screen is selected, the light is always on. When the device stops working, the lamp goes out.

Fault indicator: when the device fails, the lamp flashes and alarms. The lamp is not lighted when the equipment is working properly.


Device interface diagram



1542439201240058150.jpg


Power supply: device power supply access socket, access AC220V/50HZ or AC220V/60HZ.

Air source input: 8*6mm air duct is used to connect oxygen or air. The air source must be dry and clean, and the flow rate should not be greater than 50L/MIN.

Gas source output: 8*6mm anti-corrosive gas conduit is connected, ozone output is connected to the place users need to use.

Cooling water outlet is connected by four branch pipes and cooling water flows out.

The cooling water inlet is connected by four branch pipes and the cooling water is connected.


technical parameter

-------------------------------------------------------------------------------

Name: TS-100G/H intelligent ozone machine

Working voltage: AC220V + 5%, 50/60HZ.

Power consumption: less than 1.5KW

Control mode: touch screen control.

Working mode: touch screen settings.

Air supply: dry clean oxygen or air.

Ozone output: 92% when oxygen flow rate is 30L/min, ozone output is more than 100G/H

Ambient temperature: -10 ~ 40 C

Ambient humidity: less than 85%

Outline size: 615*405*1310mm

The cooling water flow rate is greater than or equal to 10L/min, and the water temperature is not higher than the ambient temperature.

Net weight: 54KG


product mix

-------------------------------------------------------------------------------

1, the product shell is made of 304 stainless steel, with beautiful appearance, durable and humanized design.

2, large 7 inch human-machine interface touch-screen, intelligent numerical control, manual / automatic omnidirectional monitoring.

3. Flow sensor, temperature sensor, humidity sensor and ozone concentration sensor are installed inside. All values (including power supply voltage, high voltage, discharge chamber, etc.) will be fed back to touch screen in real time. The touch screen control system will automatically adjust the data analysis according to the factory settings. Intelligent integration.

4. Internal ozone generator uses narrow gap high frequency and high voltage discharge, with high efficiency, high output and high concentration. The high voltage power supply yield ratio can be as high as 7-8KW.h/kg O 3.

5. The dielectric material is made of high-purity silica quartz material at high temperature, with high precision, uniform discharge, 316L stainless steel inner electrode and compact firmware, PTFE gas nozzle, corrosion-resistant high-purity fluorine rubber ring seal, and the latest solar aluminum alloy heat dissipation technology (patent No. 201030271620.1) is used for external air cooling and heat dissipation. For a long time, the ozone attenuation is ultra low < 5/100, and the service life is long, up to 12000 hours.

6. Characteristics of high voltage power supply: IGBT drive, automatic/manual bandwidth, slow start, (limit surge current), power supply overvoltage protection, power converter overheating protection, output short circuit, circuit breaking protection. Circuit anti-interference, moisture-proof, anti-corrosion design.


Operation instructions of touch screen control center


1, the boot screen is as follows: (background LOGO can be set according to customer requirements)


      

1542439275221071504.jpg


 

Select the corresponding menu button to enter the corresponding language interface. This note takes Chinese as an example.


2. After selecting the "enter" or "Enter" interface, the picture is as follows:

 

1542439339216024542.jpg

 

Touch to select the interface that needs to be entered:

System parameter setting

Alarm parameter setting

Working interface

Alarm browsing

Buzzer on / off

Return


3, system parameter setting (after entering the interface can set the system time, backlight duration)


1542439373929064385.jpg

 

4. Setting alarm parameters (set alarm parameters here, when leaving the factory, the equipment is in good condition, if there is no abnormality, do not debug the reference data of goods)


1542439393164090974.jpg

 

参考值:

最大工作电压

230V

最大气源湿度

85%RH

最大工作电流

5500mA

最大臭氧浓度

300mg/L

最高发生器温度

60℃

臭氧浓度显示比例

100mg/L


5、工作界面:


1542439531178050978.jpg

 

This interface is a working interface, the corresponding key functions are as follows: (before operation, please ensure that there is no alarm, if there is an alarm, check according to the screen prompt, between start, make sure that the cooling water is smooth, the air source is open, the flowmeter is open,)

Start button: under manual mode, press this button to start the ozone generator.

Stop button: press this button to stop the ozone generator.

Manual and automatic buttons: press this button to switch between manual and automatic functions.

A. The default mode of the system is the automatic mode of operation. Press the exit button below to convert the mode.

B, working time settings can be clicked in the corresponding digital position, and the corresponding data is adjusted.

C, in any way, the power adjustment is manual.

Output + button: press this button, the production progress bar will add 1 until 10.

Output button: press this button, the production progress bar will be reduced by 1 until 0.

Return key: the system will switch to the previous interface.

Work mode key: press this button to enter work mode:



1542439563519082510.jpg


  

The working time is set in sequence. The upper and lower limits of ozone concentration regulation are set. The upper limit must be higher than the lower limit. Otherwise, it will not work (reference data: the upper limit is 300 mg/L, the lower limit is 0 mg/l).


6, alarm browsing (record every ozone generator failure time and fault location).



1542439602499084696.jpg


7. Buzzer on / off.

Press this button to turn on or turn off the buzzer that has failed to alarm.


8. Return

Pressing this key will return to the previous working interface.


Instructions for equipment use

-------------------------------------------------------------------------------

TS-100G/H intelligent ozone machine is a humanized ideal equipment for water treatment and air treatment sterilization and purification. It is widely used in pure water treatment, sewage treatment, pharmaceutical industry operating room, aseptic workshop, food processing industry, storage room, fungus culture room, aquaculture farm, large laundry, large hotel, central air conditioning and so on.


Equipment installation instructions

-------------------------------------------------------------------------------

1, the equipment should be placed in a dry, clean, well ventilated environment where the temperature is not greater than 45 degrees.

2. Connect the cooling water inlet and outlet pipes, connect the air source (oxygen or air) pipes, connect the power supply lines, and ensure that there is no leakage of water and gas pipes. Open the machine protection switch. At this time, the touch screen control center begins to display the use interface.

3. Manually click on the touch screen to enter the system and set up the working time, circulation state, ozone output concentration, output value, etc. After setting up, you can choose to start work. At this time, the machine will automatically work according to the value you set, and monitor according to the protection data set at the time of leaving the factory. Once there is a fault in a link, the machine will alarm and show on the screen that there is a fault in that part, and stop the high-voltage discharge work to ensure the installation. Prepare for normal and stable use, omnibearing intelligent monitoring and control.


Points for attention

-------------------------------------------------------------------------------

1. After sealing, check whether the random accessories are complete and the equipment is in good condition according to the packing list.

2, do not collision during moving, so as not to damage.

3. If the equipment does not need to be installed for the time being, please do not remove the plastic film on the machine and store it in a dry and ventilated place.

4, equipment installed in a well ventilated clean environment, can not be inverted or flat. Installation location can not be poured by rainwater and environment humidity is greater than 90%.

5, prohibit the use in inflammable and explosive places.

6. It is forbidden to block the ventilator of the machine. Otherwise, it will affect the temperature of the ozone generator inside the machine, which will lead to the decrease of ozone concentration and shorten the service life.

7. Ozone is a strong oxidant. The ozone concentration from ozone outlet is high. People should not contact ozone for long. Ozone thrown into airtight space can decompose naturally after the machine stops working for 60 minutes, so that people can enter.

8. Non-professionals, please do not open the chassis. General electricians need to consult professional ozone maintenance personnel before they can open the chassis.


Daily maintenance of equipment

-------------------------------------------------------------------------------

1. The equipment should be placed in a dry, ventilated and clean environment, with ambient temperature ranging from - 10 to 40 degrees Celsius and relative humidity less than 85%.

2. When maintaining equipment, it is necessary to disconnect cooling water, supply voltage, oxygen cylinder or air compressor.

3. Check ventilation exhaust on equipment regularly. If there is more dust, remove it and clean it up in time and put it back in place.

4. The equipment can work continuously for 24 hours for a long time, but make sure that the cooling water flow is normal, the water temperature is normal (not higher than the ambient temperature), and the heat dissipation and ventilation on the equipment are good.

5, the wet towel used for cleaning the chassis must be twisted dry and used. Do not splash the water into the machine.


上一页