200G/H touch screen intelligent ozone machine

200G/H touch screen intelligent ozone machine
  • 产品介绍

technical parameter

-------------------------------------------------------------------------------

Name: TS-200G/H intelligent ozone machine

Working voltage: AC220V/50HZ, AC220V/60HZ, AC110V/60HZ. Choose one of them.

Power consumption: less than 2.2KW

Air supply: dry clean oxygen or air.

Ozone output: 92% when oxygen flow rate is 60L/min, ozone output is more than 200G/H

When the air flow rate is 120L/MIN, the ozone output is more than 60G/H

Working environment temperature: -10 ~ 40 C

Working environment humidity: less than 85%

Outline size: 750*550*1360mm

The cooling water flow rate is greater than or equal to 15L/min, and the water temperature is not higher than the ambient temperature.

Gross weight / net weight: 100KG/92KG


product mix

-------------------------------------------------------------------------------

1, the product shell is made of 304 stainless steel, with beautiful appearance, durable and humanized design.

2, large 7 inch human-machine interface touch-screen, intelligent numerical control, manual / automatic omnidirectional monitoring.

3. There are water pressure sensor, air pressure sensor, temperature sensor, humidity sensor (ozone concentration sensor), all the values (including power supply voltage, current, high voltage, discharge chamber working condition, gas source pressure, whether cooling water is opened, using environmental temperature, using environmental humidity, ozone tube temperature rise). Real-time feedback to the touch screen, the touch screen control system will automatically adjust the data analysis according to the factory settings to achieve intelligent integration.

4. Internal ozone generator uses narrow gap high frequency and high voltage discharge, with high efficiency, high output and high concentration. The high voltage power supply yield ratio can be as high as 7-8KW.h/kg O 3.

5. The dielectric material is made of dehydroxylated silica quartz material at high temperature, with high precision and uniform discharge. 316L stainless steel inner electrode and tight firmware, PTFE firmware, 316/304 stainless steel joint, corrosion-resistant high-purity fluorine rubber ring seal, external air-cooled heat dissipation adopts our company's patented solar aluminium alloy heat dissipation technology (patent number). 2010 030271620.1), effective heat dissipation, long-term work ozone attenuation is ultra-low < 5/100, long service life, up to 32,000 hours.

6. Characteristics of high voltage power supply: IGBT drive, automatic/manual bandwidth, slow start, (limit surge current), power supply overvoltage protection, power converter overheating protection, output short circuit, circuit breaking protection. Circuit anti-interference, moisture-proof, anti-corrosion design.

7. Characteristic of high-pressure package: It uses amorphous material, with low temperature rise, small volume and weak radiation interference. It has stable performance and long service life compared with traditional black core winding.

8. The 10MM epoxy glass brazing plate is used as the fixing plate for insulation installation. It has high structural strength and long service life. The ozone discharge tube is installed with high-voltage insulating pad and withstands 20KV. The withstand voltage is far greater than the maximum of the high-voltage of the ozone power supply, which ensures the safety performance of the equipment to the greatest extent.

9. Use four sets of 60G/H ozone suite to install. The highest yield can reach 240G/H, ensuring enough output.

10, the internal ozone connection pipe is stainless steel or tetrafluoroethylene material. Corrosion resistance and long service life.


Ozone installation drawings


1542440045012097969.png

1542440053524071081.png

1542440063162026615.png

1542440070804037294.png

1542440081329071289.png

1542440088674089757.png

1542440096082074645.png

1542440103224016698.png

1542440110062015585.png

Operation instructions of touch screen control center


1, the boot screen is as follows: (background LOGO can be set according to customer requirements)


 

1542439275221071504.jpg


  选择相应菜单按扭进入相应语言界面,本说明以中文为例

2、选择“进入”或“Enter”界面之后,画面如下:

 

1542439339216024542.jpg

 

Touch to select the interface that needs to be entered:

System parameter setting

Alarm parameter setting

Working interface

Alarm browsing

Buzzer on / off

Return


3, system parameter setting (after entering the interface can set the system time, backlight duration)


1542439373929064385.jpg


4. Setting alarm parameters (set alarm parameters here, when leaving the factory, the equipment is in good condition, if there is no abnormality, do not debug the reference data of goods)


1542439393164090974.jpg


参考值:


最大工作电压

230V

最大气源湿度

85%RH

最大工作电流

12000mA

最大臭氧浓度

300mg/L

最高发生器温度

60℃

臭氧浓度显示比例

100mg/L


5、工作界面:


1542439531178050978.jpg


 

This interface is a working interface, the corresponding key functions are as follows: (before operation, please ensure that there is no alarm, if there is an alarm, check according to the screen prompt, between start, make sure that the cooling water is smooth, the air source is open, the flowmeter is open,)

Start button: under manual mode, press this button to start the ozone generator.

Stop button: press this button to stop the ozone generator.

Manual and automatic buttons: press this button to switch between manual and automatic functions.

A. The default mode of the system is the automatic mode of operation. Press the exit button below to convert the mode.

B, working time settings can be clicked in the corresponding digital position, and the corresponding data is adjusted.

C, in any way, the power adjustment is manual.

Output + button: press this button, the production progress bar will add 1 until 10.

Output button: press this button, the production progress bar will be reduced by 1 until 0.

Return key: the system will switch to the previous interface.

Work mode key: press this button to enter work mode:


 

1542439563519082510.jpg


  工作时间按顺序设置,臭氧浓度调节分上、下限设置,上限一定要高于下限,否则不工作(参考数据:上限300mg/L,下限0mg/l)。

 

6、报警浏览 (记录每一次臭氧发生器故障的时间和故障的位置)


1542439602499084696.jpg


7. Buzzer on / off.

Press this button to turn on or turn off the buzzer that has failed to alarm.


8. Return

Pressing this key will return to the previous working interface.


Instructions for equipment use

-------------------------------------------------------------------------------

TS-100G/H intelligent ozone machine is a humanized ideal equipment for water treatment and air treatment sterilization and purification. It is widely used in pure water treatment, sewage treatment, pharmaceutical industry operating room, aseptic workshop, food processing industry, storage room, fungus culture room, aquaculture farm, large laundry, large hotel, central air conditioning and so on.


Equipment installation instructions

-------------------------------------------------------------------------------

1, the equipment should be placed in a dry, clean, well ventilated environment where the temperature is not greater than 45 degrees.

2. Connect the cooling water inlet and outlet pipes, connect the air source (oxygen or air) pipes, connect the power supply lines, and ensure that there is no leakage of water and gas pipes. Open the machine protection switch. At this time, the touch screen control center begins to display the use interface.

3. Manually click on the touch screen to enter the system and set up the working time, circulation state, ozone output concentration, output value, etc. After setting up, you can choose to start work. At this time, the machine will automatically work according to the value you set, and monitor according to the protection data set at the time of leaving the factory. Once there is a fault in a link, the machine will alarm and show on the screen that there is a fault in that part, and stop the high-voltage discharge work to ensure the installation. Prepare for normal and stable use, omnibearing intelligent monitoring and control.


Points for attention

-------------------------------------------------------------------------------

1. After sealing, check whether the random accessories are complete and the equipment is in good condition according to the packing list.

2, do not collision during moving, so as not to damage.

3. If the equipment does not need to be installed for the time being, please do not remove the plastic film on the machine and store it in a dry and ventilated place.

4, equipment installed in a well ventilated clean environment, can not be inverted or flat. Installation location can not be poured by rainwater and environment humidity is greater than 90%.

5, prohibit the use in inflammable and explosive places.

6. It is forbidden to block the ventilator of the machine. Otherwise, it will affect the temperature of the ozone generator inside the machine, which will lead to the decrease of ozone concentration and shorten the service life.

7. Ozone is a strong oxidant. The ozone concentration from ozone outlet is high. People should not contact ozone for long. Ozone thrown into airtight space can decompose naturally after the machine stops working for 60 minutes, so that people can enter.

8. Non-professionals, please do not open the chassis. General electricians need to consult professional ozone maintenance personnel before they can open the chassis.


Daily maintenance of equipment

-------------------------------------------------------------------------------

1. The equipment should be placed in a dry, ventilated and clean environment, with ambient temperature ranging from - 10 to 40 degrees Celsius and relative humidity less than 85%.

2. When maintaining equipment, it is necessary to disconnect cooling water, supply voltage, oxygen cylinder or air compressor.

3. Check ventilation exhaust on equipment regularly. If there is more dust, remove it and clean it up in time and put it back in place.

4. The equipment can work continuously for 24 hours for a long time, but make sure that the cooling water flow is normal, the water temperature is normal (not higher than the ambient temperature), and the heat dissipation and ventilation on the equipment are good.

5, the wet towel used for cleaning the chassis must be twisted dry and used. Do not splash the water into the machine.


上一页